MTC

 

Sequence Valve

 

Hydraulic Sequence Valve

Installation information

The ‘P’ port connects to the outlet port of the first actuator and the ‘T’ port connects to the inlet port of the second actuator.

Features

  • Aluminium Body
  • Cartridge Relief range 40 to 210 Bar
  • No Leakage

Operation

When the first actuator exceeds the pre-set pressure, the valve opens and allows flow to second actuator. To adjust the setting of the spring, remove the cap from the end of the cartridge and adjust clockwise to increase the setting and anti-clockwise to reduce the setting. A free flow check allows reverse flow from port ‘T’ to port ‘P’. Setting range 40 to 210 BAR.

Part Number
Port Size (BSP)
Max Flow (Litres/Min)
Maximum Pressure (BAR)
VS3502B1
3/8"
35
210
VS3503B1
1/2"
35
210

 

Specifications

VS 35 Sequence valve

 

 

 

Sequence Valve

 

Sequence Valve diagram

 
 